The structure of monel 400 (UNS N04400, NCu30) alloy is a high-strength single-phase solid solution, which is a nickel based corrosion resistant alloy used in industry very early. Monel 400 (with good comprehensive performance and wide application range, it has become an indispensable alloy due to its good corrosion resistance. Monel 400 is mainly composed of Ni, 30% Cu and a small amount of Fe (1% - 2%).

U-shaped Monel 400 tubes are commonly used in various heat exchange equipment, boiler feed water heaters, pipelines, containers, pumps, valves, shafts, etc. in petroleum and chemical processing, seawater desalination equipment, salt production equipment, propeller shafts, Gasoline and water tanks, etc.



U-shaped Monel 400 Tube|B163 UNS N04400 Tube Chemical Composition

%

C

Si

Mn

Ni

Cu

Fe

Min

 

 

 

63

28

 

Max

0.3

0.5

2

 

34

2.5

U-shaped Monel 400 Tube|B163 UNS N04400 Tube corresponding grade

Monel400

 

 

 

Ni68Cu28Fe

JIS

ASTM

UNSSAE

DIN

EN

NW4400

N0.4400

MONEL400

2.436

NiCu30Fe

Physical properties of U-shaped Monel 400 Tube|B163 UNS N04400 Tube

Specific heat J/kg.K)

20

427

Resistivity(μΩ.cm)

 

54.7

Thermal conductivity (W/m.K)

 

21.8

Average thermal expansion coefficient10-6/℃)

20-100

13.9

Melting point(℃)

 

1300-1500

Mechanical properties of U-shaped Monel 400 Tube|B163 UNS N04400 Tube at room temperature

0.2%Yield StrengthN/mm2)

Tensile Strength (N/mm2)

Elongation%

Rockwell Hardness

193

483

≤35

B75 max

U-shaped Monel 400 Tube|B163 UNS N04400 Tube Usages

U-shaped Monel 400 Tube|B163 UNS N04400 Tube can be used in many industrial fields:

1. Seamless water pipes, steam pipes in power plants

2. Seawater exchangers and evaporators

3. Sulfuric acid and hydrochloric acid environments

4. Crude oil distillation

5. Deep sea Pump shafts and propellers for water use equipment

6. Equipment used in the nuclear industry to manufacture uranium extraction and isotope separation

7. Pumps and valves used in the manufacture of hydrochloric acid equipment

8. Marine structure surface, seawater desalination/salt/right oil refining Equipment, marine components, heat exchangers, chemical/seawater desalination plant valves, pump components, etc.

Comments

Popular posts from this blog

What is membrane water wall panel?

What is membrane water wall panel? The Membrane water wall pane l is the main heating part of the boiler, which is composed of several rows of steel tubes, distributed around the boiler furnace. Its interior is flowing water or steam, and the outside receives the heat from the flame in the boiler furnace. It mainly absorbs the radiant heat of high-temperature combustion products in the furnace, in which the working medium rises and evaporates. Membrane water wall panel refers to the water wall composed of a gas tight pipe panel welded by flat steel and tubes. The membrane water wall can ensure the furnace has good tightness and can significantly reduce the air leakage coefficient of the furnace and improve the combustion conditions in the furnace for negative pressure boilers. The utility model can increase the effective radiation heating area, thereby saving the steel consumption. Advantages of Membrane water wall panel (1) The membrane water wall has the most complete protective effe...

What are the components of finned tube bundle?

The heat exchange unit composed of multiple finned tubes arranged according to certain rules is called finned tube bundle. A finned tube heat exchanger can be composed of one or more finned tube bundles. Understanding the finned tube bundles is helpful to the application of finned tube heat exchangers.   What are the components of finned tube bundle?   1. Multiple finned tubes: basic elements of heat transfer;   2. Tube box header or tube plate: connect the box, elbow or steel plate at both ends of the finned tube. When the finned tube is connected with the box or tube plate, the spacing between the finned tubes is fixed, and the tube box makes the fluid in the tube form a continuous flow channel;   3. Frame: support and fix the whole finned tube bundle.   The finned tube bundle is the main part of the air cooler, which is composed of finned tubes, tube boxes and frames. It is an independent structural whole. Its basic parameters include the tube bundle type (us...

What is tube sheet layout?

What is tube sheet layout? A tube sheet is a component used in shell and tube heat exchangers and other types of heat transfer equipment. It is a flat plate with holes drilled in it, through which tubes are inserted and secured. The tube sheet serves as a barrier between the two fluids, allowing heat to be transferred from one to the other. The layout of the tube sheet depends on the design of the heat exchanger, which includes the number of tubes, the size of the tubes, and the spacing between the tubes. The layout is typically determined using computer-aided design (CAD) software, which can optimize the placement of the tubes to achieve the desired heat transfer performance. In general, the tubes are arranged in a triangular or square pattern on the tube sheet. The triangular pattern is often preferred because it provides better support for the tubes and reduces the risk of vibration and damage. The spacing between the tubes is also important, as it affects the flow rate and pressure...