Floating coil heat exchanger

Floating coil radiators can be widely used in boilers in heating, air conditioning and hot water supply systems in industrial and civil buildings such as chemical, oil refining, shipbuilding and other factories as well as hotels, restaurants, office buildings, school scientific research buildings, Yiyuan outpatient wards and other buildings. It is used as heat exchange equipment in rooms, heat exchange station buildings and air-conditioning machine rooms.

Floating coil heat exchanger application scope

1. The heat exchanger shell has two types: ordinary steel plate and stainless steel plate, and the heat transfer tube bundles are all copper tubes.

2. The tube side design pressure of the heat exchanger is 0.1-0.9MPa for steam type and ≤1.6MPa for water-water type; the shell is equipped with three specifications of 0.6MPa, 1.0MPa and 1.6MPa respectively. When selecting equipment, pay attention to the heat source and equipment. performance to match.

3. Due to the high heat transfer efficiency of this heat exchanger, a temperature regulator (i.e. thermostat) must be installed on the steam inlet pipe of the heat exchanger to control the steam flow and hot water outlet temperature.

4. The transportation and installation of the heat exchanger must use lifting equipment such as cranes to strictly prevent rolling. The heat exchanger should be firmly fixed to the foundation to prevent vibration during operation. Maintenance locations should be left around the heat exchanger.

Features of floating coil heat exchanger

(1) Using a new structure of floating coil bundles, the heat transfer capacity is improved, and the automatic descaling ability is greatly improved;

(2) The pipe bundles can be connected using union joints, which reduces welding points and makes maintenance more convenient;

(3) Compact structure, small size and small floor space.

Materials of floating coil heat exchanger

The shell material is carbon steel or stainless steel, and the heat exchange tube material is copper. Customized floating coil heat exchangers with special materials, heat exchange areas and working pressure levels.

Comments

Popular posts from this blog

What is membrane water wall panel?

What is membrane water wall panel? The Membrane water wall pane l is the main heating part of the boiler, which is composed of several rows of steel tubes, distributed around the boiler furnace. Its interior is flowing water or steam, and the outside receives the heat from the flame in the boiler furnace. It mainly absorbs the radiant heat of high-temperature combustion products in the furnace, in which the working medium rises and evaporates. Membrane water wall panel refers to the water wall composed of a gas tight pipe panel welded by flat steel and tubes. The membrane water wall can ensure the furnace has good tightness and can significantly reduce the air leakage coefficient of the furnace and improve the combustion conditions in the furnace for negative pressure boilers. The utility model can increase the effective radiation heating area, thereby saving the steel consumption. Advantages of Membrane water wall panel (1) The membrane water wall has the most complete protective effe...

What are the components of finned tube bundle?

The heat exchange unit composed of multiple finned tubes arranged according to certain rules is called finned tube bundle. A finned tube heat exchanger can be composed of one or more finned tube bundles. Understanding the finned tube bundles is helpful to the application of finned tube heat exchangers.   What are the components of finned tube bundle?   1. Multiple finned tubes: basic elements of heat transfer;   2. Tube box header or tube plate: connect the box, elbow or steel plate at both ends of the finned tube. When the finned tube is connected with the box or tube plate, the spacing between the finned tubes is fixed, and the tube box makes the fluid in the tube form a continuous flow channel;   3. Frame: support and fix the whole finned tube bundle.   The finned tube bundle is the main part of the air cooler, which is composed of finned tubes, tube boxes and frames. It is an independent structural whole. Its basic parameters include the tube bundle type (us...

What is tube sheet layout?

What is tube sheet layout? A tube sheet is a component used in shell and tube heat exchangers and other types of heat transfer equipment. It is a flat plate with holes drilled in it, through which tubes are inserted and secured. The tube sheet serves as a barrier between the two fluids, allowing heat to be transferred from one to the other. The layout of the tube sheet depends on the design of the heat exchanger, which includes the number of tubes, the size of the tubes, and the spacing between the tubes. The layout is typically determined using computer-aided design (CAD) software, which can optimize the placement of the tubes to achieve the desired heat transfer performance. In general, the tubes are arranged in a triangular or square pattern on the tube sheet. The triangular pattern is often preferred because it provides better support for the tubes and reduces the risk of vibration and damage. The spacing between the tubes is also important, as it affects the flow rate and pressure...